  • Аrmoured control cables | AST
    accessories Tools Products Аrmoured control cables Cable makeup КВБбШв АКВБбШв КВБбШвнг АКВБбШвнг КВБбШвнг LS АКВБбШвнг LS Nominal Voltage 0 66 kV Testing voltage 3 kV Temperature range during installation not lower than 15 С during operation 50 С 50 С Bending radius when installing 10хШ cable Cross sectional area mm2 Tweet Back If You have any questions about product You can write us Partners Site Map Home Contacts About Us

    Original URL path: http://www.a-st.am/en/%d0%b0rmoured-control-cables/ (2016-02-17)
    Open archived version from archive


  • Halogen free fire resistant cables | AST
    E30 HXCH FE 180 E90 Nominal voltage 0 6 1 0 kV Testing voltage 4kV 50 Hz Temperature range during instalation not lower than 15 С for HXH FE180 E30 N HXH FE 180 E30 HXH FE 180 E90 N HXH FE 180 E90 and up to 15 С for HXCH FE 180 E30 HXCH FE 180 E90 cables during operation from 30 С to 50 С Maximum conductor temperature 90 С short circuit not more than 250 С 4 seconds in emergency state not higher than 130 С 8 hours per day Bending radius minimum single core cables of 20хШ cables multicore cables of 15хШ cables Cross sectional area mm2 from 2 x1 5 to 5 x240 Application These cables are used in places with high fire safety requirements for single and bundled cables laid in apartments tunnels trays pipes flexible sleeves in the absence of mechanical damage danger Construction Conductive copper wire Organosilicate rubber insulation which is ceramisied during the fire in HXH FE180 E90 N HXH FE180 E90 и HXCH FE 180 E90 cables Filling with halogen free fire retardant composition Polymer cable sheath which doesn t contain halogen In HXCH FE 180 E30 HXCH FE 180

    Original URL path: http://www.a-st.am/en/halogen-free-fire-resistant-cables/ (2016-02-17)
    Open archived version from archive

  • halogen free fire retardant cables | AST
    radius minimum single core cables of 20хШ cables multicore cables of 15хШ cables Cross sectional area mm2 from 2 x1 5 to 5 x240 Application The cables are designed for installation in industrial and office premises where computers and other microprocessor based equipment are installed as well as in underground facilities residential and public buildings theaters medical and educational institutions shops etc with high requirements on fire safety Construction Conductive

    Original URL path: http://www.a-st.am/en/halogen-free-fire-retardant-cables/ (2016-02-17)
    Open archived version from archive

  • Installation wires | AST
    during operation from 50 C to 70 C conductor heating not higher than at 70 C Cross sectional area mm2 АПВ АПВнг LS 2 5 120 ПВ1 ПВ3 ПВ1нг LS ПВ3нг LS 0 5 95 ППВ ППВнг LS from 2 0 75 to 3 4 АППВ АППВнг LS from 2 2 5 to 3 6 Application Wires are used for electrical equipment for fixed laying of cables in lighting and power networks as well as for the installation of electrical equipment machinery tools and machines with nominal voltage of 450 V for networks up to 450 750 V with frequency up to 400 HZ or with direct current voltage up to 1000 V In places with high requirement of fire safety ПВ3нг LS ППВнг LS АППВнг LS for inflexible installation cables are applied The wire of АПВ cable is intended to be lain in steel pipes cavitated conduits of building structures trays etc for mounting of electrical circuits In places with fire safety high requirement АПВнг LS ПВ1нг LS cables are applied Construction Conductive aluminium wire single wire АППВ АППВнг LS stranded wire АПВ АПВнг LS Conductive copper wire stranded wire ПВ1 ПВ3 ПВ1нг LS ПВ3нг LS single wire ППВ

    Original URL path: http://www.a-st.am/en/installation-wires/ (2016-02-17)
    Open archived version from archive

  • Connecting wires and cords | AST
    5 for ПВС from 2 0 5 to 3 0 75 for ШВВП from 2 0 5 to 2 0 75 for ШВП Application These wires are used to connect electric machines and devices of household and analogous use PVC wires are used in the networks with nominal AC voltage with up to 380 V for 380 660V systems and ШВВП and ШВП cords for 220 380 systems Construction Conductive

    Original URL path: http://www.a-st.am/en/connecting-wires-and-cords/ (2016-02-17)
    Open archived version from archive

  • Power Cables | AST
    during operation from 50 С to 50 С Bending radius minimum single core cables of 10хШ cables multicore cables of 7 5хШ cables Cross sectional area mm2 from 1 1 0 to 4 240 1 50 Application Transmission and distribution of electricity in fixed electrical installations with nominal voltage of 0 66 and 1 kV nominal frequency of 50 Hz For laying in dry and wet industrial areas cable racks blocks as well as for laying cables outdoors ВВГнг АВВГнг ВВГнг LS АВВГнг LS cables are used for electrical supply of electricity generating plants with high requirement on fire safety ВБбШв АВБбШв ВБбШвнг АВБбШвнг ВБбШвнг LS АВБбШвнг LS armored cables are used in cable work in the premises and facilities of the underground for laying cables in the ground when there is no stretching force during the operation Construction Conductive wire aluminium or copper wire single or stranded cable conductor circular form Polyvinylchloride elastron PVC insulation Insulation of multicore cable conductor has а distinctive colouring or numeric labelling Insulated conductors are twisted against each other Filling with PVC elastron for ВВГнг АВВГнг not sustaining combustion and for ВВГнг LS АВВГнг LS cables with low fire hazard Armor for ВБбШв АВБбШв

    Original URL path: http://www.a-st.am/en/power-cables/ (2016-02-17)
    Open archived version from archive

  • Control cables | AST
    50 С to 50 С during installation not lower than 15 С Bending radius minimum for cables up to 10 mm inclusive not less than 3хШ cables for cables from 10 to 25 mm inclusive not less than 4хШ cables Cross sectional area mm2 from 4 2 5 to 10 6 Application These cables are designed for fixed connection to electric devices equipment and assemblies of clamps of electrical distribution device with nominal AC voltage up to 660V and 100 Hz or DC voltages up to 1000 V For laying indoors trays tunnels in aggressive environment in the absence of mechanical stress on the cable It s allowed to lay the cables in the ground trenches ensuring protection of cables in the places where they come out to the surface КВВГнг АКВВГнг КВВГнг LS АКВВГнг LS cables are used when there s high requirement on fire safety Construction Conductive wire aluminium or wire single cable conductor 1st class according to SS 22483 Polyvinylchloride elastron PVC insulation Insulated conductors are twisted Every layer has а marker pair insulated conductors of which are different in colours from each other and from other conductors КВВГнг LS АКВВГнг LS cables have low smoke fire

    Original URL path: http://www.a-st.am/en/control-cables/ (2016-02-17)
    Open archived version from archive

  • Simon 15 | AST
    other more expensive series of Simon The quality of products is guaranteed throughout 91 year old history of Simon Company Child protection When wiring to the power supply network some sockets have child contact protection through shutters Lighting of switches Field for text stickers In a new series of Simon 15 frames are universal They are suitable for horizontal and vertical installation Manufacturer Simon Electric Tweet Back If You have

    Original URL path: http://www.a-st.am/en/simon-15-2/ (2016-02-17)