  • Residual Current Device PF6 and Differential Circuit Breakers PFL 6-Eaton (Moeller) | AST
    Current Device PF6 Rated current of contacts up to 63 A Nominal leakage current 30 100 300 and 500 mA Conditional stability short circuit resistance of 6 kA Differential breakers PFL 6 Combined device circuit breaker residual current device Breaking capacity of circuit breaker 6 kA Rated current of contacts up to 40 A Rated leackage current 30 mA Breaking characteristics B and C Мanufacturer Eaton Tweet Back If You

    Original URL path: http://www.a-st.am/en/residual-current-device-pf6-and-differential-circuit-breakers-pfl-6-eaton-moeller/ (2016-02-17)
    Open archived version from archive


  • Power Circuit Breakers NZM up to 1600 A | AST
    A Circuit Breakers NZM are designed for a wide range of equipment to be protected from cables to electric motors generators and transformers both AC and DC voltage and are used as the main emergency and sectionalizing switches up to 1600A New power circuit breakers NZM 2 3 4 offer completely new opportunities for exchange and data sharing Мanufacturer Eaton Tweet Back If You have any questions about product You

    Original URL path: http://www.a-st.am/en/power-circuit-breakers-nzm-up-to-1600-a/ (2016-02-17)
    Open archived version from archive

  • New automatic circuit breakers LZM of Eaton / Moeller production | AST
    designed for distribution networks at voltage up to 415 in the current range from 20 up to 1600 A Positive differences of new series LZM increased switching capacity of up to 36 kA available in four sizes dimensions rejection of electronic trips in circuit breakers of 1 3 sizes allowed to reduce their cost significantly very fast less than 10 ms cutoff of short circuit currents Мanufacturer Eaton Tweet Back

    Original URL path: http://www.a-st.am/en/new-automatic-circuit-breakers-lzm-of-eaton-moeller-production/ (2016-02-17)
    Open archived version from archive

  • Air Circuit Breakers IZM from 630 up to 6300A | AST
    to 6300A Withdrawable type Rated current A 630 6300 The number of poles 3 4 Rated Voltage of insulation strength Ui B 1000V Rated operational voltage Ue B 690 Breaking capacity kA Icu up to 130kA Microprocessor based relay Applications system protection motor protection protection of transformers protection of generators Air circuit breakers IZM may be stationary and withdrawable Мanufacturer Eaton Tweet Back If You have any questions about product

    Original URL path: http://www.a-st.am/en/air-circuit-breakers-izm-from-630-up-to-6300a/ (2016-02-17)
    Open archived version from archive

  • Low-voltage high-power inverter with vector control (N500) | AST
    information increased intelligibility PID regulation function o Management of process parameters pressure flow speed etc via the integrated PID controller Comfortable user interface and communication o The interaction of the operator with the equipment via RS 485 o Implementation of remote control of engine via particular remote controller or PC Testing of the drive by using the modeling in accordance with the nature of the load Advanced system of the

    Original URL path: http://www.a-st.am/en/low-voltage-high-power-inverter-with-vector-control-n500/ (2016-02-17)
    Open archived version from archive

  • Modular contactors Z-SCH | AST
    Designed for wiring commutations devices of lighting heating cooling ventilation at single phase or three phase loads with rated current up to 63 A Voltage of controlling coil 24V 230V 50 Hz Rated current of contacts from 25 up to 63 A 250 V AC for AC 1 Rated voltage of contacts 440V 50 Hz Мanufacturer Eaton Tweet Back If You have any questions about product You can write us

    Original URL path: http://www.a-st.am/en/modular-contactors-z-sch/ (2016-02-17)
    Open archived version from archive

  • Miniature Series | AST
    4 1 N 3 N Characteristic I In B C D Breaking capacity 3 10 kA Operating current 1 125A Leakage current protection RCCB The number of poles 2 4 Operating current 25 63A Diff current 10 500mA Leakage current protection device with automatic switch RCBO Number of poles 1 N Feature I In B C D Working current 1 40A Differential Current 10 500 mA Tweet Back If You

    Original URL path: http://www.a-st.am/en/miniature-series/ (2016-02-17)
    Open archived version from archive

  • Starting assembly for direct start of engines | AST
    Cable accessories Tools Products Starting assembly for direct start of engines Starting assembly for direct start of engines consists of an automatic circuit breaker for protection of PKZMO and contactor DILMA Rated current 0 21 up to 3 29 A Engine capacity 0 6 up to 15kW Мanufacturer Eaton Tweet Back If You have any questions about product You can write us Partners Site Map Home Contacts About Us Products

    Original URL path: http://www.a-st.am/en/starting-assembly-for-direct-start-of-engines/ (2016-02-17)
    Open archived version from archive